The development of modern diesel engines has followed exhaust emission standards (Euro 4, Euro 5 and Euro 6), and new technologies and devices have emerged that meet increasingly strict environmental protection requirements.

Advantages:

Stages of the professional cleaning process for DPF, FAP and SCR devices:
The video is played via YouTube. When you load it, Google may set its own cookies.
Through chemical reactions and physical processes, under the right conditions these devices can remove harmful exhaust gases and solid particles almost completely.
The DOC is the first device in the system. It is a flow-through ceramic honeycomb filter containing precious metals (catalysts) that start the oxidation of harmful hydrocarbons and carbon monoxide and the burning of unburnt fuel and oil.
The DPF is the second device in the system, which traps the remaining soot that the DOC could not oxidise. The soot stays in it until it is regenerated - passively or actively.

Passive regeneration takes place at normal engine operating temperature, with the DPF burning the particles at 275 to 360⁰C.
Active regeneration takes place when sensors detect excessive particle build-up and increased back pressure inside the DPF. Additional fuel is then injected into the engine to reach a temperature above 600⁰C in order to burn off the accumulated soot.
After the soot particles in the DPF have burnt, the increased back pressure drops to its normal value, but ash remains until it is removed!
But with every active regeneration cycle the ash deposits grow, the DPF becomes red-hot, fuel consumption rises, and the increased back pressure damages the turbocharger. At the same time, unburnt fuel accumulates in the oil, which reduces its viscosity and raises its level. This worsens lubrication and accelerates engine wear.
The longer the ash stays in the DPF, the greater the likelihood that it hardens and blocks the flow of exhaust gases, causing harmful back pressure.
A faulty filter is identified by monitoring regeneration cycles and measuring back pressure with diagnostic equipment.
The SCR, the last device in the system, uses an additive to contribute to the further breakdown of harmful gases and particles.
The selective reduction catalyst (SCR) usually becomes clogged with crystallised combustion deposits, because the additive (AdBlue) has run out in the tank or the dosing device has failed.

The most common causes of failures of DOC, DPF and SCR devices:
For servicing and cleaning of DPF filters contact us by phone on +385 1 2995 244, via the form at the bottom of the page Send an enquiry or by e-mail: servis@pinjusic.hr